Home Up Call me back Contents Contact Immunology / Infectious agents / Cellular Biology / Molecular biology / Instruments / Lentiviral Technology / RNAi Libreries / Stem Cell Research / MicroRNA / Proteomics / Chemicals / Campaign / Antibodiesautolab starplus AutoLab eLyte ESR 2010 ESR 2010

Google

       Pricelist 2010 

Up
autolab starplus
AutoLab eLyte
ESR 2010

redcoon België GENTAUR BVBA

VAT BE0473327336

Av. de l Armee 68 B4

1040 Brussels BELGIUM

  Tel + 32 16 58 90 45 

Fax + 32 16 50 90 45

GENTAUR France SARL

SIRET 48423788800017

Rue Lagrange, 9

75005 Paris, France

 Tel 01 43 25 01 50

Fax 01 43 25 01 60 

GENTAUR Germany

52074 Aachen, Germany

 Tel +32 16 58 90 45

Fax +32 16 50 90 45

GENTAUR Pol Sp. Z.o.o. Ulica Ogarna 15/19B m2

80-826 GDANSK

Tel 00 48 51 760 77 08

Fax: 00 32 16 50 90 45

GENTAUR Italy

23015 Milano, Italy

 Tel 02 36 00 65 93

Fax 02 36 00 65 94

Česká republika Praha
+420246019719
 

Danmark

+4569918806 

Finland Helsset
+358942419041

Ελλάς Αθήνα
+302111768494
 

Ireland Dublin
+35316526556
 

Luxembourg
+35220880274
 

Magyarország Budapest
+3619980547
 

Nederland
+31208080893
 

Norge Oslo
+4721031366
 

Österreich
+43720880899
 

Sverige Stockholm
+46852503438
 

Schweiz Züri
+41435006251
 

 

Northern America 

Canada Montreal
+15149077481
 

US New York
+17185132983

 

Other Countries redcoon België
0032 (0)16 41 44 07

 

ESR 2010
Automated Erythrocyte Sedimentation Rate Analyzer
  
Features:

  • Automated ESR analyzer based on the modified Westergren method
  • ESR results auto-corrected at 18 °C
  • Reliable and accurate results in 30 minutes
  • Excellent correlation to the standard 1 hour Westergren method
  • Useful for creating Safe and Healthy Environment for the user
  • Maintenance free

Technical Specifications:
 
Application area: Blood Sedimentation Rate Analysis
ESR tubes: 9/120mm, 1.6ml Vacuum/Non-vacuum ESR
Loading Capacity: Maximum 10 samples
Loading Pattern: Random Access
Throughput: 20 samples per hour
Analysis time: 30 minutes
Results: In Westergren mm/hour (by interpolation)
Test Tube: 1.1ml -1.28 ml blood (Non-vacuum ESR tube)
Temperature correction: Results autocorrected to 18 C (Manley Table)
Measurement principle: Infrared (IR) detection, transmission reading at start and during 30 minutes of sedimentation
Reading resolution: +/- 0.2 mm; Result resolution: +/- 1 mm
Measurement range: 1 – 140 mm/hr*; Reproducibility: C.V < 5%
Display: LCD with backlight
Interface: LPT for printer
Standard Operating Temperature: 15 °C to 30 °C
Dimensions (w x h x d): 22 cm x 21.6 cm x 17.5 cm
Weight: 2.5 kg
Power Requirements, External power supply : 110-220V AC

Note: Design; colour and Technical Spesification are subject to change without prior notice.
 

 